7. Magnets developed for CERN, Switzerland:
Total 80 numbers of vertical beam orbit corrector magnets (MCVs) for Large Electron-Positron (LEP) Collider and 5 numbers of H-type dipole magnets (2 types) for Compact Linear Collider (CLIC) test facility were developed as per the specifications of CERN, Switzerland and delivered MCVs in the year 1996 & dipole magnets in the year 2004.
Parameters of MCV magnets
Parameter
| Value
|
Magnetic field
| 0.038 T
|
Pole gap
| 200 mm
|
Yoke length
| 400 mm
|
Coil turns (N)
| 2420 Nos.
|
Current (I)
| 2.5 A (Max.)
|
Magnet mass
| ~ 110 kg
|
Power loss
| 160 W
|
Fig. 87: MCV Core assemblies at RRCAT (L) and testing of magnets at CERN, Swiss (R).
Fig. 88: Dipole Magnet developed for CLIC test facility, CERN.
Fig. 89: Dipole Magnet (red) developed by AMTD installed in TL-2 at CERN.
Fig. 90: Measured magnetic field uniformity in dipole magnet (R).
|